#PAGE_PARAMS# #ADS_HEAD_SCRIPTS# #MICRODATA#

Cyclic loading test study on a new cast-in-situ insulated sandwich concrete wall


Autoři: Wentao Qiao aff001;  Xiaoxiang Yin aff001;  Shengying Zhao aff003;  Dong Wang aff004
Působiště autorů: School of Civil Engineering, Shi Jiazhuang Tiedao University, Shi Jiazhuang, China aff001;  Cooperative Innovation Center of Disaster Prevention and Mitigation for Large Infrastructure in Hebei Province (Shi Jiazhuang Tiedao University), Shi Jiazhuang, China aff002;  School of Civil Engineering, Harbin Institute of Technology, Harbin, China aff003;  TRC Companies, Baton Rouge, United States of America aff004
Vyšlo v časopise: PLoS ONE 14(11)
Kategorie: Research Article
doi: https://doi.org/10.1371/journal.pone.0225055

Souhrn

Insulated sandwich concrete panel (ISCP) is widely used because of its high thermal insulation efficiency and low construction cost. Aiming at improving traditional ISCP, a new cast-in-situ concrete wall structure made of ISCP is proposed, which is composed of thin-walled cold-formed steels, slant steel wire connectors, steel wire meshes, concrete layers, expanded polystyrene sheets and reinforced concrete embedded columns. In order to assess the hysteretic properties of the new insulated sandwich concrete wall and the influence of various parameters, low-frequency horizontal cyclic load tests were carried out on seven full-scale specimens of new type cast-in-situ insulated sandwich concrete wall. The specimens were compared and analyzed with respect to failure mode, bearing capacity, ductility, degradation characteristics and energy dissipation capacity. The results show that the final failure pattern of the specimen is two main diagonal cracks intersecting each other; the bearing capacity is greatly affected by concrete thickness and axial compression ratio, regardless of concrete strength. Brittle failure is typically observed when the steel wire spacing is large, while ductility is pronounced when the concrete layer thickness is small and the concrete strength is low; the smaller the thickness of concrete layer, the faster the stiffness degrades. The wall structure shows a better energy dissipation performance with a smaller steel wire spacing, lower concrete strength and smaller axial compression ratio.

Klíčová slova:

Built structures – Composite materials – Compression – Concrete – Deformation – Polystyrene – Steel – Stiffness


Zdroje

1. Zhai X, Wang Y, Wang X. Thermal performance of precast concrete sandwich walls with a novel hybrid connector. Energy Build. 2018, 166, 109–121.

2. Tomlinson D, Fam A. Analysis and Parametric Study of Partially Composite Precast Concrete Sandwich Panels under Axial Loads. J. Struct. Eng. 2016, 142, 04016086:1–04016086:15.

3. Tomlinson D, Fam A. Analytical approach to flexural response of partially composite insulated concrete sandwich walls used for cladding. Eng. Struct. 2016, 122, 251–266.

4. Choi W, Jang S, Yun H. Design properties of insulated precast concrete sandwich panels with composite shear connectors. Compos. Part B Eng. 2019, 157, 36–42.

5. Choi I, Kim J, Kim H. Composite Behavior of Insulated Concrete Sandwich Wall Panels Subjected to Wind Pressure and Suction. Materials 2015, 8, 1264–1282. doi: 10.3390/ma8031264 28788001

6. Choi I, Kim J, You Y. Effect of cyclic loading on composite behavior of insulated concrete sandwich wall panels with GFRP shear connectors. Compos. Part B Eng. 2016, 96, 7–19.

7. Colombo IG, Colombo M, Prisco MD, Pouyaei F. Analytical and numerical prediction of the bending behaviour of textile reinforced concrete sandwich beams. J. Build. Eng. 2018, 17, 183–195.

8. Vervloet J, Tysmans T, El Kadi M, De Munck M, Kapsalis P, Van Itterbeeck P, et al. Validation of a Numerical Bending Model for Sandwich Beams with Textile-Reinforced Cement Faces by Means of Digital Image Correlation. Appl. Sci. 2019, 9, 1253:1–1253:16.

9. Xie Q, Wang S, Liu C. Axial Compression Behavior of a New Type of Prefabricated Concrete Sandwich Wall Panel. IOP Conf. Ser.: Mater. Sci. Eng. 2018, 317, 012063:1–012063:6.

10. Norris TG, Chen A. Development of insulated FRP-confined Precast Concrete Sandwich panel with side and top confining plates and dry bond. Compos. Struct. 2016, 152, 444–454.

11. Jiang H, Guo Z, Liu J. Composite Behavior of Sandwich Panels with W-Shaped SGFRP Connectors. KSCE J. Civ. Eng. 2018, 22, 1889–1899.

12. Lameiras R, Barros J, Valente IB, Azenha M. Development of sandwich panels combining fibre reinforced concrete layers and fibre reinforced polymer connectors. Part I: Conception and pull-out tests. Compos. Struct. 2013, 105, 446–459.

13. Lameiras R, Barros J, Azenha M, Valente IB. Development of sandwich panels combining fibre reinforced concrete layers and fibre reinforced polymer connectors. Part II: Evaluation of mechanical behaviour. Compos. Struct. 2013, 105, 460–470.

14. Huang J, Dai J. Direct Shear Tests of Glass Fiber Reinforced Polymer Connectors for Use in Precast Concrete Sandwich Panels. Energy. Build. 2019, 207, 136–147.

15. Chen A, Norris TG, Hopkins PM, Yossef M. Experimental investigation and finite element analysis of flexural behavior of insulated concrete sandwich panels with FRP plate shear connectors. Eng. Struct. 2015, 98, 95–108.

16. Joseph JDR, Prabakar J, Alagusundaramoorthy P. Experimental studies on through-thickness shear behavior of EPS based precast concrete sandwich panels with truss shear connectors. Compos. Part B Eng. 2019, 166, 446–456.

17. Flansbjer M, Portal WN, Vennetti D, Mueller U. Composite Behaviour of Textile Reinforced Reactive Powder Concrete Sandwich Façade Elements. Int. J. Concr. Struct. Mater. 2018, 12, 71:1–71:17.

18. Flansbjer M, Williams Portal N, Vennetti D. Verification of the Structural Performance of Textile Reinforced Reactive Powder Concrete Sandwich Facade Elements. Appl. Sci. 2019, 9, 2456:1–2456:26.

19. Pavese A, Bournas DA. Experimental assessment of the seismic performance of a prefabricated concrete structural wall system. Eng. Struct. 2011, 33, 2049–2062.

20. Ricci I, Palermo M, Gasparini G, Silvestri S, Trombetti T. Results of pseudo-static tests with cyclic horizontal load on cast in situ sandwich squat concrete walls. Eng. Struct. 2013, 54, 131–149.

21. Palermo M, Ricci I, Silvestri S, Gasparini G, Trombetti T, Foti D, Salvador I. Preliminary interpretation of shaking-table response of a full-scale 3-storey building composed of thin reinforced concrete sandwich walls. Eng. Struct. 2014, 76, 75–89.

22. Hashemi SJ, Razzaghi J, Moghadam AS, Lourenço PB. Cyclic testing of steel frames infilled with concrete sandwich panels. Arch. Civil Mech. Eng. 2018, 18, 557–572.

23. Lu Z, Wang Y, Li J, Wang L. Experimental study on seismic performance of L-shaped insulated concrete sandwich shear wall with a horizontal seam. Struct. Design Tall Spec. Build. 2019, 28, e1551:1–e1551:12.

24. Abbas A, Adil M, Ahmad N, Ahmad I. Behavior of reinforced concrete sandwiched panels (RCSPs) under blast load. Eng. Struct. 2019, 181, 476–490.

25. Guo Z, Shi X. Principle and analysis of reinforced concrete, 1st ed.; Tsinghua university press; 2003; pp. 335–337.

26. China Academy of Building Research. Specification of Testing Method for Earthquake Resistant Building, JGJ 101–96; China Architecture & Building Press; 1996; pp. 9–15.


Článek vyšel v časopise

PLOS One


2019 Číslo 11
Nejčtenější tento týden
Nejčtenější v tomto čísle
Kurzy

Zvyšte si kvalifikaci online z pohodlí domova

plice
INSIGHTS from European Respiratory Congress
nový kurz

Současné pohledy na riziko v parodontologii
Autoři: MUDr. Ladislav Korábek, CSc., MBA

Svět praktické medicíny 3/2024 (znalostní test z časopisu)

Kardiologické projevy hypereozinofilií
Autoři: prof. MUDr. Petr Němec, Ph.D.

Střevní příprava před kolonoskopií
Autoři: MUDr. Klára Kmochová, Ph.D.

Všechny kurzy
Kurzy Podcasty Doporučená témata Časopisy
Přihlášení
Zapomenuté heslo

Zadejte e-mailovou adresu, se kterou jste vytvářel(a) účet, budou Vám na ni zaslány informace k nastavení nového hesla.

Přihlášení

Nemáte účet?  Registrujte se

#ADS_BOTTOM_SCRIPTS#