#PAGE_PARAMS# #ADS_HEAD_SCRIPTS# #MICRODATA#

Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and Adjustable Continence Therapy (ProACT) for male stress incontinence


Authors: Javier C. Angulo aff001;  Sandra Schönburg aff003;  Alessandro Giammò aff004;  Francisco J. Abellán aff001;  Ignacio Arance aff001;  David Lora aff005
Authors place of work: Departamento Clínico, Universidad Europea de Madrid, Madrid aff001;  Servicio de Urología, Hospital Universitario de Getafe, Madrid, Spain aff002;  Department of Urology and Kidney Transplantation, Martin Luther University, Halle (Saale), Germany aff003;  Department of Neuro-Urology, CTO-Spinal Unit, Città della Salute e della Scienza di Torino, Turin, Italy aff004;  Instituto de Investigación Sanitaria Hospital "12 de Octubre" (i+12), Madrid, Spain aff005;  CIBER de Epidemiología y Salud Pública (CIBERESP), Madrid, Spain aff006;  Universidad Complutense de Madrid, Madrid, Spain aff007
Published in the journal: PLoS ONE 14(12)
Category: Research Article
doi: https://doi.org/10.1371/journal.pone.0225762

Summary

Background and purpose

Urinary incontinence is one of the most serious complications of prostate cancer treatment. The objective of this study was to assess efficacy and safety of Adjustable Transobturator Male System (ATOMS) compared to Adjustable Continence Therapy (proACT) for male stress urinary incotinence according to literature findings.

Material and methods

A systematic review and meta-analysis on adjustable devices ATOMS and ProACT is presented. Studies on female or neurogenic incontinence were excluded. Differences between ATOMS and proACT in primary objective: dryness status (no-pad or one safety pad/day) after initial device adjustment, and in secondary objectives: improvement, satisfaction, complications and device durability, were estimated using random-effect model. Statistical heterogeneity among studies included in the meta-analysis was assessed using tau2, Higgins´s I2 statistics and Cochran´s Q test.

Results

Combined data of 41 observational studies with 3059 patients showed higher dryness (68 vs. 55%; p = .01) and improvement (91 vs. 80%; p = .007) rate for ATOMS than ProACT. Mean pad-count (-4 vs. -2.5 pads/day; p = .005) and pad-test decrease (-425.7 vs. -211.4 cc; p < .0001) were also significantly lower. Satisfaction was higher for ATOMS (87 vs. 56%; p = .002) and explant rate was higher for proACT (5 vs. 24%; p < .0001). Complication rate for ProACT was also higher, but not statistically significant (17 vs. 26%; p = .07). Mean follow-up was 25.7 months, lower for ATOMS than ProACT (20.8 vs. 30.6 months; p = .02). The rate of working devices favoured ATOMS at 1-year (92 vs. 76; p < .0001), 2-years (85 vs. 61%; p = .0008) and 3-years (81 vs. 58%; p = .0001). Significant heterogeneity was evidenced, due to variable incontinence severity baseline, difficulties for a common reporting of complications, different number of adjustments and time of follow-up and absence of randomized studies.

Conclusions

Despite the limitations that studies available are exclusively descriptive and the follow-up is limited, literature findings confirm ATOMS is more efficacious, with higher patient satisfaction and better durability than ProACT to treat male stress incontinence.

Keywords:

Patients – Cancer treatment – Systematic reviews – Medical devices and equipment – Surgical and invasive medical procedures – Publication ethics – Incontinence

Introduction

Urinary incontinence can severely impact the quality of life of prostate cancer survivors after radical prostatectomy and/or radiotherapy [1,2]. The artificial urinary sphincter (AUS) has been the main therapy after failed conservative treatment but reposition of the posterior urethra using retrobulbar slings has been a great revolution [3]. Also development of new devices usig postoperative adjustment has allowed a more personalized approach. Systematic reviews on the topic tend to annalyze a variety of devices with different modes of action [47].

Adjustable continence therapy (ProACT®, Uromedica, Minneapolis, MN) using balloons placed periurethraly near the bladder neck was the first adjustable implant to treat stress incontinence. It consists of two volume-adjustable balloons, that increase urethral resistance during voiding. Adjustable transobturator male system (ATOMS®, A.M.I., Feldkirch, Austria) is another adjustable device that compresses the bulbar urethra ventrally but, unlike ProACT, its two-arm mesh allows firm transobturator fixation on both sides of the ischio-pubic bone. Both devices can be adjusted postoperatively without need for aneasthesia. Besides, they open a new perspective of treatment for patients with cognitive impairment and/or limited dexterity, as no manipulation is needed for voiding [8]. Unfortunately, prospective controlled studies comparing anti-incontinence devices are lacking [9].

ATOMS and ProACT share two important peculiarities. Their mode of action is through urethral compression, and both are easily adjusted postoperatively by percutaneous injection of sterile saline solution until continence or a maximun filling volume is accomplished. Their main differences stand in that compression is ventral in ATOMS and lateral (both sides) in ProACT, and also that ATOMS is fixed to the pelvis while ProACT is a non-fixed device. ProACT has longer been used as its first description for male stress incontinence was in 2005 [10] and ATOMS started in 2011 [8]. ProACT remains unchanged but several modifications have been undertaken in ATOMS port location and design, evolving from inguinal to scrotal and silicone-covered.

Randomized comparative studies between ProACT or ATOMS have not been performed to date but a number of individual or multi-center studies with same or very similar endpoints covered are available for both devices. With this study we aim to evaluate the current evidence on the efficacy and safety ATOMS compared to ProACT using a systematic review approach and meta-analysis.

Materials and methods

A systematic review of the scientific literature was carried out in September 2019. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) checklist is included (S1 Table). The search included studies published between January 2005 and August 2019. The search was undertaken in PubMed, Embase, Web of Science and Scopus. Search strategy was designed according to PICOS criteria (Population, Intervention, Comparator, Outcomes and Study Design) (Table 1) for the identification of studies using free and controlled terminology. Search strategy included the terms: “Urinary incontinence” AND “male” AND “ATOMS” OR “ProACT”. A manual revision of the bibliographic references was also carried out. We included prospective and retrospective, multi-centre or single-centre case series, published in English, Spanish, German or Italian on patients treated with ATOMS or ProACT devices for SUI after prostate surgery. No clinical trial on the topic could be found. Duplicate studies, editorial comments, letters to the editor or expert opinions in non-systematic reviews, a report after cystoprostatectomy and a meta-analysis centered only on ATOMS were excluded.

Tab. 1. PICOS criteria to guide the systematic review.
PICOS criteria to guide the systematic review.

The identification, selection and extraction of data from the studies were carried out exhaustively and independently by two reviewers. A first selection of the studies was performed by reading the title and the abstract, and those that met the inclusion criteria were reviewed by reading the full text. Disagreements were resolved by consensus or in collaboration with another member of the research team. Consecutive publications from the same groups were evaluated to avoid overlapping of patients in different studies. Whenever repetition was detected we only used the last publication with larger number of patients. The evidence was summarized with the data extracted from the studies that included bibliographic information, characteristics of the study and patients, characteristics of the intervention, and outcome measures in relation to the efficacy and safety of the procedure. The definitions of postoperative dryness and improvement were comparable among studies. Differential pad-count or differential 24h pad-test was calculated as after adjustment minus baseline when available, assuming both values are non-dependent. Safety was defined according to rate of explantation and complications.

Primary efficacy indicator was percentage of dry patients after adjustment, defined as patients using no pad or only one safety pad/day (PPD). When dry rate change evolution in time was described in a study only the initial report was used. Main secondary efficacy outcome was percentage of overall improvement (defined as ≥50% decrease in pad-count and/or in 24h pad-test). Differential pad-count and differential 24h pad-test between baseline and after adjustment were investigated to evaluate the magnitude effect. The proportion of patients satisfied with the intervention, complication rate, explantation rate, number of adjustments, follow-up after implantation and durability of the devices were also evaluated as secondary outcomes. We also included an analysis of manuscript quality assessment using the Newcastle-Ottawa scale.

The heterogeneity assumption was evaluated by the chi-square-based Cochran’s Q test (which was considered significant at p-value < .05), and quantified with the I2 statistic (with values <25%, 25% to 75%, and >75% interpreted as representing low, moderate and high levels of heterogeneity, respectively), and with tau2 (the between-study variance) that was obtained with the DerSimonian and Laird method. Due to the presence of heterogeneity, random-effects model with the inverse variance method was used for pooling of single proportions, single means or mean differences from primary studies. The pooled effect was described with 95% confidence interval (CI). Publication bias was assessed by visual inspection of funnel plots and quantified by the Egger's linear regression test. Statistical analysis and figures were performed with the meta package of R software version 3.4.1 (R Foundation for Statistical Computing, Vienna, Austria) [11].

Results

Literature search

The search initially provided 174 references, 61 of which dealt with the topic evaluated. Additional records identified 6 further references through other sources. The reason for exclusion was multiple. Three studies were duplicated and 13 were not considered eligible (11 did not meet inclusion criteria and 2 were previous non-updated meta-analysis). Besides, 10 full-text articles were excluded for several reasons: 2 described the operative technique and urodynamic data but did not provide information to be included, 1 used different devices simultaneously, 1 was a case report with an unusual complication, 3 were pilot studies published before the definite article included and 3 were post-hoc studies of primary reports already included that focused on specific results (patient reported outcomes, stratification of results according to different generation of devices and a subgroup of patients with longer follow-up) (Fig 1).

Fig. 1. Flow chart with studies included in the systematic review.
Flow chart with studies included in the systematic review.

Characteristics of the studies

Tables 2 and 3 show the characteristics of the 41 selected studies, published between 2005 and 2019, that include 3059 patients in total. Twenty-one articles were published using ProACT [1232] and 20 using ATOMS [3352]. No study was randomized controlled, and there was no comparison reported among these or other devices. The main etiology of incontinence was radical prostatectomy but other causes were included. Also the percentage of radiated patients and the degree of baseline incontinence was variable. Dryness rate and improvement rate were very homogeneously reported among the studies. The proportion of patients self-considering satisfied with the device was also often specified; however, 24-h pad-count and, more interestingly, pad-test (baseline, after adjustment and differential) was absent in some studies. The Freeman-Tukey arcsine transform was developed (S1 Fig) and pooled proportion (dryness, improvement, satisfaction, explant and complication rates) and mean (number of fillings, differential pad-count and differential pad-test) with 95% confidence intervals were used as summary effect measure.

Tab. 2. Studies with ProACT included in the meta-analysis and variables evaluated.
Studies with ProACT included in the meta-analysis and variables evaluated.
Tab. 3. Studies with ATOMS included in the meta-analysis and variables evaluated.
Studies with ATOMS included in the meta-analysis and variables evaluated.

Tables 4 and 5 summarize the different domains to evaluate study quality. Observational cohorts available have been analyzed according to the Newcastle-Ottawa Scale for quality assessment. None of the studies included in this meta-analysis was a randomized clinical trial and studies generally lack a nonexposed cohort or control. However, the comparision of the intervention is possible with respects to baseline situation before use of device. Attrition bias seems low and the cohorts appear comparable for outcome assessment.

Tab. 4. Newcastle-Ottawa scale for assessing the quality of cohort studies with ProACT included in the meta-analysis.
Newcastle-Ottawa scale for assessing the quality of cohort studies with ProACT included in the meta-analysis.
Tab. 5. Newcastle-Ottawa scale for assessing the quality of cohort studies with ATOMS included in the meta-analysis.
Newcastle-Ottawa scale for assessing the quality of cohort studies with ATOMS included in the meta-analysis.

Baseline characteristics

Similarities between the populations evaluated for each device were investigated to confirm the groups are comparable. Firstly, regarding baseline incontinence severity baseline pad-count for ATOMS and ProACT were equivalent (5.05 (95% CI 4.8;5.3) PPD compared to 4.6 (95% CI 3.9;5.3) PPD; p = .27). Secondly, the proportion of patients with previous surgery for incontinence was similar between devices (16.1% (95% CI 9.7;23.5) for ATOMS vs. 11% (95% CI 5.05;18.6) for ProACT; p = .29). Finally, patient age at the time of surgery was higher for ATOMS (70.8 (95% CI 69.9;71.6) years vs. 68.9 (95% CI 68.1;69.6); p = .0009), but this difference is not clinically significant.

Efficacy

Regarding the primary outcome, mean dryness rate was higher with ATOMS than ProACT (68% (95% CI 62;73) compared to 55% (95% CI 47;63); p = .01) (Fig 2). Also regarding the main secondary objective of the study, percentage of overall improvement was also higher for ATOMS than proACT (91% (95% CI 87;94) vs. 80% (95% CI 72;87; p = .007) (Fig 3). A higher proportion of patients self-declared satisfied with ATOMS as well (87% (95% CI 81;92) vs 56% (95% CI 36;76); p = .002) (Fig 4). Conversely, mean number of fillings for adjustment was lower for ATOMS than proACT (2.4 (95% CI 1.9;2.9) vs. 3.5 (95% CI 3;3.9); p = .001) (Fig 5).

Fig. 2. Forest plot of studies analyzed for dry rate.
Forest plot of studies analyzed for dry rate.
Fig. 3. Forest plot of studies analyzed for improve rate.
Forest plot of studies analyzed for improve rate.
Fig. 4. Forest plot of studies analyzed for satisfaction rate.
Forest plot of studies analyzed for satisfaction rate.
Fig. 5. Forest plot of studies analyzed with number of fillings.
Forest plot of studies analyzed with number of fillings.

Results revealing the magnitude of effect for improving urine loss are quantitatively notorious. Mean baseline pad-count was equivalent in the studies evaluated (5 PPD (95% CI 4.8;5.3) for ATOMS and 4.6 PPD (95% CI 3.9;5.3) for proACT; p = .27) but postoperative pad-count was lower for ATOMS (1.1 PPD (95% CI .9;1.3) vs. 2.1 PPD (95% CI 1.7;2.5); p < .0001). Therefore, mean differential pad-count was also lower for ATOMS (-4 PPD (95% CI -4.4;-3.7) vs. -2.5 PPD (95% CI (3.5;-1.5); p = .005) (Fig 6). Studies revealing mean pad-test were less numerous, especially for proACT; however, interesting data were also evidenced. Mean baseline pad-test reported was significantly higher for ATOMS (505 mL (95% CI 461;549) vs. 312 mL (95% CI 231;394); p < .0001) but postoperative pad-test became equivalent (22 mL (95% CI 13;31) for ATOMS and 91 mL (95% CI 15;186) for ProACT; p < .08). Not strikingly, mean differential pad-test was lower for ATOMS (-426 mL (95% CI -462;-389) vs. -211 mL (95% CI -312;-111); p < .0001) (Fig 7).

Fig. 6. Forest plot of studies analyzed with differential pad-count in pads-per-day.
Forest plot of studies analyzed with differential pad-count in pads-per-day.
Fig. 7. Forest plot of studies analyzed with differential pad-test expressed in mL.
Forest plot of studies analyzed with differential pad-test expressed in mL.

Risk of publication bias was not identified for primary efficacy outcome, and variables evaluating the effect magnitude (differential pad-test and differential pad-count) (S2 Table). However, significant heterogeneity was detected in all variables evaluated (S3 Table), what possibly depends on different baseline severity of incontinence and patient profile, use of differrent generation devices for ATOMS and also different technique to appropriately place ProACT as described in the literature. Only randomization could reduce these biases.

Safety and device durability

Mean follow-up was 25.7 months (95% CI 22.7;28.7), lower for ATOMS than ProACT (20.8 months (95% CI 17.1;24.5) vs. 30.6 months (95% CI 23;38.1); p = .02). The studies presented interesting safety results, both on explatation and complications. Mean explant rate was significantly lower for ATOMS (5% (95% CI 2;9) vs. 25% (95% CI 19;31); p < .0001) (Fig 8). Complication rate was also lower for ATOMS, but without reaching statistical significance (17% (95% CI 13;22) vs. 26% (95% CI 18;34); p = 0.067) (Fig 9). Similarly, major complication rate was similar between devices 4.2% (95% CI 1.7;7.7) for ATOMS vs. 10.4% (95% CI 3.15;20.7) for ProACT; p = 0.15). Risk of publication bias was not identified for these safety outcomes, but significant heterogeneity was probably related to the variability in reporting complications among studies (S2 Table, S3 Table),

Fig. 8. Forest plot of studies analyzed for explant rate.
Forest plot of studies analyzed for explant rate.
Fig. 9. Forest plot of studies analyzed for complication rate.
Forest plot of studies analyzed for complication rate.

Only 4 studies reveal strong data on durability (2 for each device) and specific analysis of Kaplan-Meier curves given and number of patients at risk allows to compare the proportio of devices that continue working in place, was higher for ATOMS on 1-year (92% (95% CI 87;96) vs. 76% (95% CI 69;83); p < .0001), 2-years (85% (95% CI 74;93) vs. 61% (95% CI 52;70); p = .0008) and 3-years (81% (95% CI 73;87) vs. 58% (95% CI 48;67); p < .0001) (Fig 10).

Fig. 10.
Forest plot of studies analyzed with durability of the devices at 12-months (A), 24-months (B) and 36-months (C).

Discussion

Despite male SUI therapy is an area of increasing interest the overall risk of bias must be reported as the majority of studies available about all male incontinence devices including AUS, slings and adjustable devices are retrospective or quasi prospective and mostly single center uncontrolled cohorts. In the absence of randomized controlled trials systematic reviews and meta-analysis can provide better evidence than simple prospective cohorts. Even though, systematic reviews on the topic are scarce and confusing as tend to compile multiple devices with very different mode of action [4]. Also reviews are often biased to compare AUS and other devices, sometimes all named under the misleading term “slings”. Adjustable slings developed to achieve urethral tensioning and results can be satisfactory even in severe incontinence and/or previous irradiation. However, current evidence is not firm to consider they are more efficacious than fixed male slings [6,7].

Both ProACT and ATOMS are really adjustable devices and unlike the AUS exert a non-circumferential periurethral compression that can be increased postoperatively in an office-based setting without re-intervention. The patient carries out urination without manipulation and the risk of mechanical failure is minimal, due to simplicity. Recent systematic reviews and meta-analysis confirm both ATOMS and ProACT are efficacious and safe alternatives to treat male stress incontinence of different degree but provide no comparison between them [53,54]. Interestingly, individual data reported for each device in those meta-analysis is very consistent with data here presented.

ATOMS has been implanted in Europe for a decade. It is used in mild and moderate-to-severe SUI, also in patients with previous radiotherapy. However, results are better in non-radiated patients and non-severe SUI [43,47,53]. Factors determinant of best patient perception with ATOMS are postoperative dryness, severe baseline incontinence severity, non-radiation, less pain at discharge and absence of postoperative complications [55]. ProACT has been implanted for two decades in Europe and more recently in the United States, often in outpatient basis under X-ray or transrectal ultrasound guidance. Based on this minimally invasiveness it has been recommended as first-line treatment in non-irradiated patients with mild-to-moderate incontinence [6,54,56], although revision and explantation rates are high [18,27,29,30] because a correct positioning of the balloons is mandatory to achieve good results [21]. Based on our findings, ProACT does not appear to be an ideal device for durable continence or patient satisfaction. Also it is not so minimally invasive procedure as the complication rate, both total and major complications, surmounts that of ATOMS implant. A very recent experience uses ATOMS after retrieval of ProACT and indirectly supports ATOMS is superior to ProACT in the short-term [51]. What is more ATOMS can be used after radiation while ProACT is not recommended in this situation [6,31].

Pooled data in this meta-analysis reveals ATOMS is superior to ProACT in all the items evaluated for efficacy: dryness (68% vs 55%), improvement (91% vs 80%) and patient satisfaction (87% vs 56%). Definitions used as outcome measures are equivalent in most of the series analyzed (Tables 2 and 3). The magnitude of effect is also higher for ATOMS than ProACT, regarding both pad-count change (-4 vs -2.5 PPD) and pad-test change (-426 vs -211 mL). Regarding safety, ATOMS is again superior to ProACT with less explant rate (5% vs 24%) and a higher proportion of devices working in place during the first three years of follow-up.

The main limitations of this meta-analysis stand in the short follow-up, especially in the ATOMS arm, and in the very high heterogeneity observed between studies; probably reflecting a variable severity of sphincteric damage included and the absence of controlled randomized studies. Also the critria to report complications appear variable between the studies analyzed. The limitations highlighted are in consonance with the publication bias identified according to Egger’s linear regression. Despite the existing limitations, we consider this meta-analysis can be of great help both for physicians and health care providers.

Conclusion

The decision upon which is the best device to treat male stress incontinence in a particular patient is influenced by patient status, manual dexterity, incontinence severity and previous radiotherapy. According to this systematic review and meta-analysis both the ProACT and the ATOMS system appear efficacious and safe procedures to treat male stress incontinence. However, taking into account the statistical summary of effect size ATOMS is a more efficacious alternative compared to ProACT with higher dryness, improvement and patient satisfaction rates, lower explant rate and higher durability. It must however be noted that the ATOMS studies have shorter follow-up than the ProACT studies.

Supporting information

S1 Table [doc]
Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2009 Checklist.

S2 Table [docx]
Assessment of the risk of publication bias by means of Egger’s linear regression test for the study outcomes evaluated.

S3 Table [docx]
Random effect model (proportion estimate, 95% Confidence Interval) and quantifying heterogeneity (I2, p-value) for the study outcomes evaluated.

S1 Fig [a]


Zdroje

1. Marzorati C, Monzani D, Mazzocco K, Pavan F, Cozzi G, De Cobelli O, et al. Predicting trajectories of recovery in prostate cancer patients undergone Robot-Assisted Radical Prostatectomy (RARP). PLoS One. 2019 Apr 4;14(4):e0214682. doi: 10.1371/journal.pone.0214682 30946773

2. Schaake W, van der Schaaf A, van Dijk LV, van den Bergh ACM, Langendijk JA. Development of a prediction model for late urinary incontinence, hematuria, pain and voiding frequency among irradiated prostate cancer patients. PLoS One. 2018 Jul 17;13(7):e0197757. doi: 10.1371/journal.pone.0197757 30016325

3. Van der Aa F, Drake MJ, Kasyan GR, Petrolekas A, Cornu JN. Young Academic Urologists Functional Urology Group. The artificial urinary sphincter after a quarter of a century: a critical systematic review of its use in male non-neurogenic incontinence. Eur Urol. 2013;63:681–9. doi: 10.1016/j.eururo.2012.11.034 23219375

4. Crivellaro S, Morlacco A, Bodo G, Agrò EF, Gozzi C, Pistolesi D, et al. Systematic review of surgical treatment of post radical prostatectomy stress urinary incontinence. Neurourol Urodyn. 2016;35:875–881. doi: 10.1002/nau.22873 26397171

5. Chen YC, Lin PH, Jou YY, Lin VC. Surgical treatment for urinary incontinence after prostatectomy: A meta-analysis and systematic review. PLoS One. 2017 May 3;12(5):e0130867. doi: 10.1371/journal.pone.0130867 28467435

6. Kretschmer A, bner W, Sandhu JS, Bauer RM. Evaluation and management of postprostatectomy incontinence: A systematic review of current literature. Eur Urol Focus. 2016;2: 245–59. doi: 10.1016/j.euf.2016.01.002 28723370

7. Meisterhofer K, Herzog S, Strini KA, Sebastianelli L, Bauer R, Dalpiaz O. Male slings for postprostatectomy incontinence: A systematic review and meta-analysis. Eur Urol Focus. 2019 Feb 1. pii: S2405-4569(19)30008-2. [Epub ahead of print]

8. Bauer W, Brössner C. Adjustable transobturator male system (ATOMS) for the treatment of post-prostatectomy urinary incontinence: the surgical technique. Pelviperineology 2011; 30: 10–8.

9. Comiter CV, Dobberfuhl AD. The artificial urinary sphincter and male sling for postprostatectomy incontinence: Which patient should get which procedure? Investig Clin Urol. 2016;57:3–13 doi: 10.4111/icu.2016.57.1.3 26966721

10. Hübner WA. ProACT for the treatment of male SUI. In Post-prostatectomy incontinence. Evaluation and management. Singla Ajay & Comiter Craig, Editors. pp 117–123. Springer International Publishing AG 2017

11. R Core Team. R:A language and envionment for statistical computing. R Foundation for Statistical Computing.Vienna, Austria; 2016. Available from https://www.R-project.org/.

12. Hübner WA, Schlarp OM. Treatment of incontinence after prostatectomy using a new minimally invasive device: adjustable continence therapy. BJU Int. 2005;96:587–94. doi: 10.1111/j.1464-410X.2005.05689.x 16104915

13. Trigo-Rocha F, Gomes CM, Pompeo AC, Lucon AM, Arap S. Prospective study evaluating efficacy and safety of Adjustable Continence Therapy (ProACT) for post radical prostatectomy urinary incontinence. Urology. 2006;67(5):965–9. doi: 10.1016/j.urology.2005.11.011 16698356

14. Kocjancic E, Crivellaro S, Ranzoni S, Bonvini D, Gontero P, Frea B. Adjustable Continence Therapy for the treatment of male stress urinary incontinence: a single-centre study. Scand J Urol Nephrol. 2007;41:324–8. doi: 10.1080/00365590601153488 17763225

15. Lebret T, Cour F, Benchetrit J, Grise P, Bernstein J, Delaporte V, et al. Treatment of postprostatectomy stress urinary incontinence using a minimally invasive adjustable continence balloon device, ProACT: results of a preliminary, multicenter, pilot study. Urology. 2008;71:256–60. doi: 10.1016/j.urology.2007.08.062 18308096

16. Gilling PJ, Bell DF, Wilson LC, Westenberg AM, Reuther R, Fraundorfer MR. An adjustable continence therapy device for treating incontinence after prostatectomy: a minimum 2-year follow-up. BJU Int. 2008;102:1426–30. doi: 10.1111/j.1464-410X.2008.07816.x 18564132

17. Crivellaro S, Singla A, Aggarwal N, Frea B, Kocjancic E. Adjustable continence therapy (ProACT) and bone anchored male sling: Comparison of two new treatments of post prostatectomy incontinence. Int J Urol. 2008;15:910–4. doi: 10.1111/j.1442-2042.2008.02161.x 18761534

18. Martens FM, Lampe MI, Heesakkers JP. ProACT for stress urinary incontinence after radical prostatectomy. Urol Int. 2009;82:394–8. doi: 10.1159/000218526 19506404

19. Gregori A, Romanò AL, Scieri F, Pietrantuono F, Incarbone GP, Salvaggio A, et al. Transrectal ultrasound-guided implantation of Adjustable Continence Therapy (ProACT): surgical technique and clinical results after a mean follow-up of 2 years. Eur Urol. 2010;57:430–6. doi: 10.1016/j.eururo.2009.11.031 19942340

20. García Matres MJ, Cansino Alcaide JR, Monasterio S, Rodríguez de Bethencourt F, Hidalgo Togores L, de la Peña Barthel J. Paraurethral adjustable continence therapy device (Pro-ACT) in the treatment of urinary incontinence after prostatic surgery. Arch Esp Urol. 2009;62:871–81. doi: 10.4321/s0004-06142009001000012 20068264

21. Giammò A, Bodo G, Castellano S, Borrè A, Carone R. Spiral multidetector computerized tomography evaluation of adjustable continence therapy implants. J Urol. 2010;183:1921–6. doi: 10.1016/j.juro.2010.01.019 20303116

22. Rouprêt M, Misraï V, Gosseine PN, Bart S, Cour F, Chartier-Kastler E. Management of stress urinary incontinence following prostate surgery with minimally invasive adjustable continence balloon implants: functional results from a single center prospective study. J Urol. 2011;186:198–203. doi: 10.1016/j.juro.2011.03.016 21575974

23. Kjær L, Fode M, Nørgaard N, Sønksen J, Nordling J. Adjustable continence balloons: clinical results of a new minimally invasive treatment for male urinary incontinence. Scand J Urol Nephrol. 2012;46:196–200. doi: 10.3109/00365599.2012.660986 22364390

24. Crivellaro S, Tosco L, Palazzetti A, Abbinante M, Martinez G, Kocjancic E, et al. Geometrical stepper-guided navigation system for ProACT implant under transrectal ultrasound control: preliminary data. Urol Int. 2012;89:473–9. doi: 10.1159/000341991 22965196

25. Gatti L, Moroni A, Cristinelli L, Benedusi F, Antonelli A, Zani D, et al. ProACT (Adjustable Continence Therapy) implants in case of failure of other techniques for urinary incontinence. Urologia. 2012;79 Suppl 19:46–9.

26. Utomo E, Groen J, Vroom IH, van Mastrigt R, Blok BF. Urodynamic effects of volume-adjustable balloons for treatment of postprostatectomy urinary incontinence. Urology. 2013;81:1308–14. doi: 10.1016/j.urology.2013.01.020 23465144

27. Venturino L, Dalpiaz O, Pummer K, Primus G. Adjustable continence balloons in men: Adjustments do not translate into long-term continence. Urology. 2015;85:1448–52. doi: 10.1016/j.urology.2015.01.045 26099887

28. Baron MG, Delcourt C, Nouhaud FX, Gillibert A, Pfister C, Grise P, et al. Sequential treatment with ProACTTM device implantation after male sling failure for male urinary incontinence. Progrès en urologie 2017;27:1098–1103. doi: 10.1016/j.purol.2017.08.001 28847446

29. Nash S, Aboseif S, Gilling P, Gretzer M, Samowitz H, Rose M, et al. Treatment with an adjustable long-term implant for post-prostatectomy stress incontinence: The ProACT™ pivotal trial. Neurourol Urodyn. 2018;37:2854–2859. doi: 10.1002/nau.23802 30178536

30. Nestler S, Thomas C, Neisius A, Rubenwolf P, Roos F, Hampel C, et al. Long-term results of ProACT primary and repeat implantation for treatment of stress urinary incontinence in men. World J Urol. 2019;37:1173–1179. doi: 10.1007/s00345-018-2483-4 30225800

31. Noordhoff TC, Scheepe JR, Blok BFM. Outcome and complications of adjustable continence therapy (proACTTM) after radical prostatectomy: 10 years’ experience in 143 patients. Neurourol Urodyn. 2018;37:1419–1425. doi: 10.1002/nau.23463 29266406

32. Finazzi Agrò E, Gregori A, Bianchi D, Carone R, Giammò A, Ammirati E, et al. Efficacy and safety of adjustable balloons (Proact™) to treat male stress urinary incontinence after prostate surgery: Medium and long-term follow-up data of a national multicentric retrospective study. Neurourol Urodyn. 2019;38:1979–1984. doi: 10.1002/nau.24103 31302928

33. Hoda MR, Primus G, Schumann A, Fischereder K, von Heyden B, Schmid N, et al. Treatment of stress urinary incontinence after radical prostatectomy: adjustable transobturator male system—results of a multicenter prospective observational study. Urologe A. 2012;51:1576–83. doi: 10.1007/s00120-012-2950-2 22836942

34. Seweryn J, Bauer W, Ponholzer A, Schramek P. Initial experience and results with a new adjustable transobturator male system for the treatment of stress urinary incontinence. J Urol. 2012;187:956–61. doi: 10.1016/j.juro.2011.10.138 22264469

35. Hoda MR, Primus G, Fischereder K, Von Heyden B, Mohammed N, Schmid N, et al. Early results of a European multicentre experience with a new self-anchoring adjustable transobturator system for treatment of stress urinary incontinence in men. BJU Int. 2013;111:296–303. doi: 10.1111/j.1464-410X.2012.11482.x 23186285

36. Krause J, Tietze S, Behrendt W, Nast J, Hamza A. Reconstructive surgery for male stress urinary incontinence: Experiences using the ATOMS(®) system at a single center. GMS Interdiscip Plast Reconstr Surg DGPW. 2014 Dec 17;3:Doc15. doi: 10.3205/iprs000056 eCollection 2014. 26504726

37. González SP, Cansino JR, Portilla MA, Rodriguez SC, Hidalgo L, De la Peña J. First experience with the ATOMS(®) implant, a new treatment option for male urinary incontinence. Cent European J Urol. 2014;67:387–91. doi: 10.5173/ceju.2014.04.art14 25667760

38. Friedl A, Bauer W, Rom M, Kivaranovic D, Lüftenegger W, Brössner C. Sexuality and erectile function after implantation of an Adjustable Transobturator Male System (ATOMS) for urinary stress incontinence. A multi-institutional prospective study. Arch Ital Urol Androl. 2016;87:306–11. doi: 10.4081/aiua.2015.4.306 26766803

39. Mühlstädt S, Friedl A, Mohammed N, Schumann A, Weigand K, Kawan F, et al. Five-year experience with the adjustable transobturator male system for the treatment of male stress urinary incontinence: a single-center evaluation. World J Urol. 2017;35:145–151. doi: 10.1007/s00345-016-1839-x 27156092

40. Friedl A, Mühlstädt S, Rom M, Kivaranovic D, Mohammed N, Fornara P, et al. Risk factors for treatment failure with the adjustable transobturator male system incontinence device: Who will succeed, Who will fail? Results of a multicenter study. Urology. 2016;90:189–94. doi: 10.1016/j.urology.2015.12.044 26773347

41. Hüsch T, Kretschmer A, Thomsen F, Kronlachner D, Kurosch M, Obaje A, et al. Debates on Male Incontinence (DOMINO)-Project. Risk factors for failure of male slings and artificial urinary sphincters: Results from a large middle European cohort study. Urol Int. 2017;99:14–21. doi: 10.1159/000449232 27598774

42. Buresova E, Vidlar A, Grepl M, Student V Jr, Student V. Single-centre experience in using the adjustable transobturator male system in treatment of stress urinary incontinence in patients after radical prostatectomy. Journal of Clinical Urology 1–7. doi: 10.1177/2051415817701054

43. Friedl A, Mühlstädt S, Zachoval R, Giammò A, Kivaranovic D, Rom M, et al. Long-term outcome of the adjustable transobturator male system (ATOMS): results of a European multicentre study. BJU Int. 2017;119:785–792. doi: 10.1111/bju.13684 27868328

44. Friedl A, Schneeweiss J, Stangl K, Mühlstädt S, Zachoval R, Hruby S, et al. The adjustable transobturator male system in stress urinary incontinence after transurethral resection of the prostate. Urology. 2017;109:184–189. doi: 10.1016/j.urology.2017.07.004 28712889

45. Angulo J, Arance I, Esquinas C, Dorado J, Marcelino J, Martins F. Outcome measures of adjustable transobturator male system with pre-attached scrotal port for male stress urinary incontinence after radical prostatectomy. Adv Ther. 2017;34: 1173–83. doi: 10.1007/s12325-017-0528-5 28405960

46. Manso M, Alexandre B, Antunes-Lopes T, Martins-da-Silva C, Cruz F. Is the adjustable transobturator system ATOMS® useful for the treatment of male urinary incontinence in low to medium volume urological centers? Actas Urol Esp. 2018;42:267–272 doi: 10.1016/j.acuro.2017.07.011 29174630

47. Angulo JC, Cruz F, Esquinas C, Arance I, Manso M, Rodríguez A, et al. Treatment of male stress urinary incontinence with the adjustable transobturator male system: Outcomes of a multi-center Iberian study. Neurourol Urodyn. 2018;37:1458–1466. doi: 10.1002/nau.23474 29315765

48. Esquinas C, Arance I, Pamplona J, Moraga A, Dorado JF, Angulo JC. Treatment of stress urinary incontinence after prostatectomy with the adjustable transobturator male system (ATOMS®) with preattached scrotal port. Actas Urol Esp 2018;42:473–82. doi: 10.1016/j.acuro.2018.02.005 29642999

49. Angulo JC, Fonseca J, Esquinas C, Ojea A, Rodríguez A, Rabassa M, et al. Adjustable transobturator male system (ATOMS®) as treatment of stress urinary incontinence secondary to transurethral resection of the prostate. Actas Urol Esp. 2018;42:567–573. doi: 10.1016/j.acuro.2018.05.002 29929737

50. Angulo JC, Esquinas C, Arance I, Rodríguez A, Pereira J, Rabassa M, et al. Adjustable transobturator male system after failed surgical devices for male stress urinary incontinence: A feasibility study. Urol Int. 2018;101:106–113 doi: 10.1159/000489316 29953998

51. Giammò A, Ammirati E, Tullio A, Bodo G, Manassero A, Gontero P, et al. Implant of ATOMS® system for the treatment of postoperative male stress urinary incontinence: results of a single centre. Int Braz J Urol.2019;45:127–136. doi: 10.1590/S1677-5538.IBJU.2018.0171 30521175

52. Doiron RC, Saavedra A, Haines T, Nadeau G, Tu LM, Morisset J, et al. Canadian Experience with the Adjustable Transobturator Male System for Post-Prostatectomy Incontinence: A Multicenter Study. J Urol. 2019 Jun 28:101097JU0000000000000420.

53. Esquinas C, Angulo JC. Effectiveness of adjustable transobturator male system (ATOMS) to treat male stress incontinence: A systematic review and meta-analysis. Adv Ther. 2019;36:426–441. doi: 10.1007/s12325-018-0852-4 30560525

54. Larson T, Jhaveri H, Yeung LL. Adjustable continence therapy (ProACT) for the treatment of male stress urinary incontinence: A systematic review and meta-analysis. Neurourol Urodyn. 2019 Aug 20. doi: 10.1002/nau.24135 [Epub ahead of print] 31429982

55. Angulo JC, Arance I, Ojea A, Carballo M, Rodríguez A, Pereira J, et al. Patient satisfaction with adjustable transobturator male system in the Iberian multicenter study. World J Urol. 2019 Jan 16. doi: 10.1007/s00345-019-02639-4 [Epub ahead of print] 30649591

56. Nash S, Aboseif S, Gilling P, Gretzer M, Samowitz H, Rose M, et al. Four-year follow-up on 68 patients with a new post-operatively adjustable long-term implant for post-prostatectomy stress incontinence: ProACT™. Neurourol Urodyn. 2019;38:248–253. doi: 10.1002/nau.23838 30311667


Článek vyšel v časopise

PLOS One


2019 Číslo 12
Nejčtenější tento týden
Nejčtenější v tomto čísle
Kurzy

Zvyšte si kvalifikaci online z pohodlí domova

plice
INSIGHTS from European Respiratory Congress
nový kurz

Současné pohledy na riziko v parodontologii
Autoři: MUDr. Ladislav Korábek, CSc., MBA

Svět praktické medicíny 3/2024 (znalostní test z časopisu)

Kardiologické projevy hypereozinofilií
Autoři: prof. MUDr. Petr Němec, Ph.D.

Střevní příprava před kolonoskopií
Autoři: MUDr. Klára Kmochová, Ph.D.

Všechny kurzy
Kurzy Podcasty Doporučená témata Časopisy
Přihlášení
Zapomenuté heslo

Zadejte e-mailovou adresu, se kterou jste vytvářel(a) účet, budou Vám na ni zaslány informace k nastavení nového hesla.

Přihlášení

Nemáte účet?  Registrujte se

#ADS_BOTTOM_SCRIPTS#