Correction: Evaluation of lung toxicity risk with computed tomography ventilation image for thoracic cancer patients
Authors:
Masakazu Otsuka; Hajime Monzen; Kenji Matsumoto; Mikoto Tamura; Masahiro Inada; Noriyuki Kadoya; Yasumasa Nishimura
Published in the journal:
PLoS ONE 14(11)
Category:
Correction
doi:
https://doi.org/10.1371/journal.pone.0225965
In the Results subsection of the Abstract, there are errors in the first two sentences. The correct sentences are: For Mean Dose, poorly ventilated lung regions in the 0–30% range showed the highest AUC value (0.809: 95% confidence interval [CI], 0.754−0.973). For V20, poorly ventilated lung regions in the 0–20% range had the highest AUC value (0.774: 95% [CI], 0.679−0.869), and for V5, poorly ventilated lung regions in the 0–30% range had the highest AUC value (0.843:95% [CI], 0.732–0.954).
There are errors in the fifth sentence of the second paragraph of the Results section. The correct sentence is: For all of the dosimetric parameters, the highest AUC values were observed for poorly ventilated regions (e.g., the 30% range for Mean Dose with the value of 0.809:95% [CI], 0.754−0.973, the 20% range for V20 with the value of 0.774:95% [CI], 0.679−0.869, and the 30% range for V5 with the value of 0.843:95% [CI], 0.732–0.954 ).
There is an error in the first sentence of the Patient characteristics subsection of the Materials and methods. The correct sentence is: This retrospective study was approved by institutional review board.
There is an error in the first sentence of the Conclusions. The correct sentence is: Our results showed that dose disposition cannot reduce lung toxicity in highly ventilated regions in contrast, dose disposition in poorly ventilated regions might be accompanied by a reduced lung toxicity risk.
There is an error in affiliation 1 for authors Masakazu Otsuka, Hajime Monzen, Kenji Matsumoto, and Mikoto Tamura. The correct affiliation 1 is: Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osakasayama, Japan.
There are errors in the captions for Figs 1–4. Please see the complete, correct captions for Figs 1–4 here.
Zdroje
1. Otsuka M, Monzen H, Matsumoto K, Tamura M, Inada M, Kadoya N, et al. (2018) Evaluation of lung toxicity risk with computed tomography ventilation image for thoracic cancer patients. PLoS ONE 13(10): e0204721. https://doi.org/10.1371/journal.pone.0204721 30281625
Článek vyšel v časopise
PLOS One
2019 Číslo 11
- S diagnostikou Parkinsonovy nemoci může nově pomoci AI nástroj pro hodnocení mrkacího reflexu
- Je libo čepici místo mozkového implantátu?
- Pomůže v budoucnu s triáží na pohotovostech umělá inteligence?
- AI může chirurgům poskytnout cenná data i zpětnou vazbu v reálném čase
- Nová metoda odlišení nádorové tkáně může zpřesnit resekci glioblastomů
Nejčtenější v tomto čísle
- A daily diary study on maladaptive daydreaming, mind wandering, and sleep disturbances: Examining within-person and between-persons relations
- A 3’ UTR SNP rs885863, a cis-eQTL for the circadian gene VIPR2 and lincRNA 689, is associated with opioid addiction
- A substitution mutation in a conserved domain of mammalian acetate-dependent acetyl CoA synthetase 2 results in destabilized protein and impaired HIF-2 signaling
- Molecular validation of clinical Pantoea isolates identified by MALDI-TOF
Zvyšte si kvalifikaci online z pohodlí domova
Všechny kurzy