Specific behaviour of the blood sedimentation processes examined by the electrochemical impedance microsensor
Authors:
Štefan Durdík 1; Vladimír Tvarožek 2; Soňa Flickyngerová 2; Daniel Donoval 2
Authors‘ workplace:
Oncology Institute of Santa Elizabeth, Bratislava, Slovakia
1; Institute of Electronics and Photonics FEI, Slovak University of Technology, Bratislava, Slovakia
2
Published in:
Lékař a technika - Clinician and Technology No. 1, 2013, 43, 39-43
Category:
Original research
Overview
Electrochemical impedance microsensor for the fast monitoring of the blood sedimentation has been developed. Planar microsensor consisted of the interdigital array of electrodes (IDAE - finger/gap widths of different values from 5/5 μm to 400/400 μm) based on Au or Pt thin films sputtered on Si/SiO2 or ceramic alumina substrates. IDAE microsensor allows time measurements of electrical impedance changes - impedance rates - (at frequencies of order 0.1 kHz and 10 kHz) of small blood drop applied on it. The determination of the impedance rate during sedimentation and the impedance spectrometry at a low-frequency range of order of 1 kHz seems to be very helpful for a quick diagnostics of the health state. In the IDAE microsensor erythrocyte aggregation/rapid settling/packing periods associated with dry-period are overlapping due to the planar arrangement of dimensions in order of 1 -100 μm. The time monitoring of the blood sedimentation (in the range of 10‑900 seconds) by the impedance method can distinguish between healthy and cancer state of blood and could serve for the simple long-term diagnostics after the surgical operation or as a screening procedure for early diagnoses.
Keywords:
planar IDAE impedance microsensor, blood sedimentation
Sources
[1] Mamishev, A., Rajan, K. S F., Du Y. Y., Zahn, M. Interdigital sensors and transducers. Proc. of the IEEE, 2004, vol. 92, no. 5, p. 808-845.
[2] Rehacek, V., Shtereva, M., Novotny, I., Tvarozek, V., Breternitz, V., Spiess, L., Knedlik, Ch. Mercury-plated thin film ITO microelectrode array for analysis of heavy metals. Vacuum, 2005, vol. 80, p. 132-136.
[3] Ivanic, R., Novotny, I., Rehacek, V., Tvarozek, V., Weis, M. Thin film non-symmetric microelectrode array for impedance monitoring of human skin. Thin Solid Films, 2003, vol. 433, p. 332-336.
[4] Tvarozek, V., Vavrinsky, E., Reznicek, Z. Novel approach in ratiometric technique of sensing. Journal of Electrical Engineering, 2007, vol. 58, no. 2, p.98-103.
[5] International Commitee for Standardization in Hematology: Recommendation for Measurement of ESR of Human Blood, Am. J. Clinical Pathology 1977, vol. 68, p. 505-507.
[6] Zhao T. X. New applications of electrical impedance of human blood. Journal of Medical Engineering & Technology, 1996, vol. 20, p. 115-120.
[7] Bertoluzzo, S. M., Bollini, A., Rasia ,M., Raynal, A., Blood Cells. Molecules and Diseases, 1999, vol. 25, no 22, p. 339-349.
[8] Baskurt, O. K., Meiselman, H. J., Kayar, E. Measurement of red blood cell aggregation in a “plate–plate” shearing system by analysis of light transmission. Clinical Hemorheology and Microcirculation, 1998, vol. 19, p. 307-314.
[9] Shin, S., Jang, J. H., Park, M. S., Ku, Y. H., Suh, J. S. A noble RBC aggregometer with vibration-induced disaggregation mechanism. Korea-Australia Rheology Journal, 2005, vol. 17, p. 9-13.
[10] Lambrechts, M., Sansen, W. Biosensors: Microelectro-chemical Devices, IOP Publishing London, New York, 1992.
[11] Flickyngerová S. Využitie mikroelektród pre impedančnú diagnostiku krvi, Diplomová práca, FEI STU Bratislava, 2005.
[12] Jakubec, A. Tenkovrstvové mikroelektródy pre biochemické impedančné mikrosenzory, Dizertačná práca, FEI STU Bratislava, 2007.
Labels
BiomedicineArticle was published in
The Clinician and Technology Journal
2013 Issue 1
Most read in this issue
- MOŽNOSTI VYUŽITÍ ANALÝZY PŘEŽÍVÁNÍ V BIOMEDICÍNĚ A TECHNICE
- 13C-methacetinový dechový test u pacientů s jaterní cirhózou a dekompenzovaným srdečním selháním
- SROVNÁNÍ RŮZNÝCH PŘÍSTUPŮ HRANOVÉ DETEKCE KONČETINOVÝCH TEPEN V PODÉLNÉM ŘEZU ULTRAZVUKOVÉHO OBRAZU
- Fototoxický vliv porfyrinových sensitizerů a viditelného záření na gram-pozitivní methicilin-rezistentní kmen S. aureus