#PAGE_PARAMS# #ADS_HEAD_SCRIPTS# #MICRODATA#

Effect of Biological Glues on Vascular Wall in an Experimental Model of Aortic Dissection


Authors: T. Martinča;  M. Jonák;  Z. Tonar 1;  K. Witter 2;  V. M. Matějka 3;  S. Rokošný
Authors‘ workplace: Klinika kardiovaskulární chirurgie, IKEM, Praha, Česká republika ;  Ústav histologie a embryologie, Lékařská fakulta UK Plzeň, Česká republika 1;  Institut für Anatomie, Histologie und Embryologie, Veterinärmedizinische Universität Wien, Österreich 2;  Ústav histologie a embryologie, Lékařská fakulta UK Plzeň, Česká republika 3
Published in: Rozhl. Chir., 2011, roč. 90, č. 2, s. 134-140.
Category: Monothematic special - Original

Overview

Introduction:
the use of biological glues and their application between the two dissection layers and into the anastomosis region is a common integral part of surgical management of thoracic aortic dissections.

Aim:
The aim of the experimental study was to assess and evaluate histopathological changes of vascular wall following deposition of the following three types of glue – GRF, Tissucol, Bioglue, based on qualitative and quantitative parameters. The secondary aim of the study was to assess dynamics of these changes depending on the glue effect duration and to formulate expected behaviour of the vascular wall during the time beyond the experimental period.

Methodology:
The dissection model was performed with pigs of the same gender and age, assigned to four groups. Different glues were used to close artificial infrarenal aortic dissections in Group 1-3, while direct suturing and no glue was used to close false lumini in Group 4. Samples of the dissected aorta were then collected at Month 1, 6 and 12 and then histologically examined.

Results:
Upon assessment of the whole group of qualitative and quantitative parameters, the most significant changes in the smooth muscle histological picture were observed with the use GRF glue. The smooth muscle changes following the Bioglue application and, in particular, Tissucol glue application, are similar to changes observed in Group 4, where no glue was used.

Conclusion:
Based on the results, the authors present a hypothesis that, in a long-time horizont, vascular wall destructions, eventually redissections, are likely to occur more frequently in patients, in whom GRF glue is used.

Key words:
experiment – biological glues – aortic dissection – histological changes


Sources

1. Trimarchi, S., Nienaber, C. A., Rampoldi, V., et al. Contemporary results of surgery in acute type A aortic dissection: The International Registry of Acute Aortic Dissection experience. J. Thorac. Cardivasc. Surg., 2005; 129: 112–122.

2. Hata, M., Takano, H., Matsumiya, G., Fukushima, N., Kawaguchi, N., Sawa, Y. Late Complications of Gelatin-Resorcin-Formalin Glue in the Repair of Acute Type A Aortic Dissection. Ann. Thorac. Surg., 2007; 83: 1621–1627.

3. Hata, M., Shiono, M., Sezai, A., Iida, M., Negishi, N., Sezai, Y. Type A Acute Aortic Dissection: Immediate and Mid-Term Results of Emergency Aortic Replacement With the Aid of Gelatin Resorcin Formalin Glue. Ann. Thorac. Surg., 2004, 78: 853–857.

4. Kaplan, M., Bozkurt, S., Kut, M. S., Kullu, S., Demirtas, M. M. Histopathological effects of ethyl 2-cyanoacrylate tissue adhesive following surgical application: an experimental study. Eur. J. Cardiothorac. Surg., 2004, 25: 167–172.

5. Bingley, J. A., Gardner, M. A. H., Stafford, E. G., Mau, T. K., Pohlner, P. G, Tam, R. K. W., Jalali, H., Tesar P. J., O’Brien, M. F. Late Complications of Tissue Glues in Aortic Surgery. Ann. Thorac. Surg., 2000, 69: 1764–1768.

6. Kirsch, M., Ginat, M. Lecerf, L., Houel, R., Loisance, D. Aortic Wall Alterations After Use of Gelatin-Resorcinol-Formalin Glue. Ann. Thorac. Surg., 2002, 73: 642–644.

7. Blanton, F. S., Muller, W. H. Jr., Warren, W. D. Experimental production of dissecting aneurysms of the aorta. Surgery, 1959, 45: 81–90.

8. Stary, H. C. Natural History and histological Classification of Atherosclerotic Lesions. An Update. Arterioscler. Thromb. Vasc. ­Biol., 2000, 20: 1177–1178.

9. Stoyan, D., Kendall, W. S., Mecke, J.: Stochastic geometry and its applications. 2nd ed., John Wiley & Sons, New York, 1995, 456 pp.

10. Kazui, T., Washiyama, N., Bashar, A. H. M., Terada, H., Suzuki, K., Yamashita, K., Takinami, M. Role of Biologic Glue Repair of Proximal Aortic Dissection in the Development of Early and Midterm Redissection of the Aortic Root. Ann. Thorac. Surg., 2001, 72: 509–514.

11. Yoshitatsu, M., Nomura, F., Katayama, A., Tamura, K., Katayama, K., Ihara, K., Nakashima, Y. Pathologic findings of aortic redissection after glue repair of proximal aorta. J. Thorac. Cardiovasc. Surg., 2004, 127: 593–595.

12. Fukunaga, S., Karck, M., Harringer, W., Cremer, J., Rhein, C., Haverich, A. The use of gelatin-resorcin-formalin glue in acute aortic dissection type A. Eur. J. Cardiothorac. Surg., 1999, 15: 564–570.

13. Kunihara, T., Shiiya, N., Matsuzaki, K., Murashita, T., Matsui, Y. Recommendation for Apropriate Use of GRF Glue in the Operation for Acute Aortic Dissection. Ann. Thorac. Cardiovasc. Surg., 2008; 14: 88–95.

14. Oz, M. C., Cosgrove, D. M., Badduke, B. R., Hill, D., Flannery, M. R., Palumbo, R., Topic, N. Controlled clinical trial of a novel hemostatic agent in cardiac surgery. Ann. Thorac. Surg., 2000, 69: 1376–1382.

15. Hewit, C. W., Marra, S. W., Kann, B. R., Tran, H. S., Puc, M. M., Chrazanowski, F. A. Jr., Tran, J. L., Lenz, S. D., Cilley, J. H. Jr., Simonetti, V. A., DelRossi, A. J. BioGlue surgical adhesive for thoracic aortic repair during coagulopathy: efficiant and histopathology. Ann. Thorac. Surg., 2001, 71: 1609–1612.

16. Coselli, J. S., Bavaria, J. E., Fehrenbacher, J., Stowe, C. L., Macheers, S. K., Gundry, S. R. Prospective randomized study of a protein-based tissue adhesive used as a hemostatic and structural adjunct in cardiac and vascular anastomotic repair procedures, Presented at the 88th Annual Clinical Congress of the American College of Surgeons, San Francisco, CA, October 2002.

17. Raanani, E., Georghiou, G. P., Kogan, A., Wandwi, B., Shapira, Y., Vidne, B. A. BioGlue for repair of aortic insufficiency in acute aortic dissection. J. Heart Valve Dis., 2004, 13: 734–737.

18. Fürst, W., Banerjee, A. Release of Glutaraldehyde From an Albumin-Glutaraldehyde Tissue Adhesive Causes Significant In Vitro and in Vivi Toxicity. Ann. Thorac. Surg., 2005; 79: 1522–1529.

19. Moringlane, J. R., Grote, R., Vonnahme, F. J., Mestres, P., Harbauer, G., Ostertag, C. B. Experimental aneurysms in the rabbit: occlusion by intrasaccular injection of fibrin sealant. Surg. Neurol., 1987, 28: 361–366.

20. Dottori, V., Spagnolo, S., Passerone, G., Lijoi, A., Barberis, L., Agostini, M., De Gaetano, G., Parodi, E., Maccario, M., Fumagalli, C. Ten years of surgery of aortic dissections and aneurysms. Clinical experience and original contributions. Minerva Cardioangiol. 1992, 40: 431–436.

Labels
Surgery Orthopaedics Trauma surgery
Topics Journals
Login
Forgotten password

Enter the email address that you registered with. We will send you instructions on how to set a new password.

Login

Don‘t have an account?  Create new account

#ADS_BOTTOM_SCRIPTS#