Introduction:
Restoring stability of the injured pelvic ring is a precondition for ensuring a good functional outcome. There are a number of stabilizing techniques including some percutaneous and minimally invasive techniques. The aim of this case-report was to present an alternative option of minimally invasive fixation of the anterior segment of the pelvis using ©MATRIX Spine System for spondylosurgical stabilization.
Materials and Methods:
This case report describes an alternative procedure of minimally invasive stabilization of the anterior pelvic segment with polyaxial screws fixed in the supra-acetabular region with a firm but fle-xible connecting rod in an obese patient with polytrauma, after embolization of the internal illiac artery with a massive hematoma in the lower abdomen.
Results:
Uncomplicated healing process. After 12 months thepatient is without difficulties and there is no hardware-related irritation. He does not request hardware removal.
Conclusion:
Minimally invasive pelvic stabilization of the anterior segment using the ©MATRIX Spine System expands the repertoire of fixation options for pelvic ring injuries.
Key word:
MISS, pelvic fracture, symphysiolysis, minimally invasive, internal fixation.
Sources
1. COLE, P A., GAUGER, EM., ANAVIAN, J.,et al Anterior pelvic external fixat or versus subcutaneous internal fixator in the treatment of anterior ring pelvic fractures. J Orthop Trauma. 2012, 5, 269–277.
2. COLLINGE, C., ARCHDEACON, M. T., DULANEY-CRIPE, E. et al. Radiographic changes of implant failure after plating for pubic symphysis diastasis: an underappreciated reality? Clinical Orthop. 2012, 8, 2148–2153. ISSN 1528-1132.
3. FRANK, M., DEDEK, T., TRLICA, J. et al. Perkutánní osteosyntéza předního pilíře acetabula - první zkušenosti. Acta Chir Orthop Traum Čech. 2010, 2, 99–104. ISSN 0001-5415
4. GARDNER, MJ., MEHTA, S., MIRZA, A., et al. Anterior pelvic reduction and fixation using a subcutaneous internal fixator. J Orthop Trauma. 2012, 5, 314–321. ISSN 1531-2291
5. HIESTERMAN, T. G., HILL, B. W., COLE, P. A. Surgical technique: a percutaneous method of subcutaneous fixation for the anterior pelvic ring: the pelvic bridge. Clin Orthop. 2012, 8, 2116–2123. ISSN 1528-1132
6. KELLAM, J. F. The role of external fixation in pelvic disruptions. Clin Orthop. 1989, 241, 66–82. ISSN 0009-921X.
7. KUTTNER, M., KLAIBER, A., LORENZ, T. et al. The pelvic subcutaneous cross-over internal fixator. Der Unfallchirurg. 2009, 7, 661–669. ISSN 1433-044X.
8. LINDAHL, J., HIRVENSALO, E., BÖSTMAN, O. et al. Failure of reduction with an external fixator in the management of injuries of the pelvic ring. Long- term evaluation of 110 patients. J Bone Joint Surg Br. 1999, 6, 955–962. ISSN 0301-620X.
9. MASON, WT., KHAN, SN., JAMES, CL et al Complications of temporary and definitive external fixation of pelvic ring injuries. Injury. 2005, 36, 599–604. ISSN 0020-1383.
10. SAGI, H., PAPP, C., PAPP, S. Comparative Radiographic and Clinical Outcome of Two-Hole and Multi-Hole Symphyseal Plating. J Orthop Trauma. 2008, 6, 373–378. ISSN 0890-5339.
11. TALLER, S., LUKÁŠ, R., ŠRÁM, J. Samostatné kanylované šrouby při stabilizaci zlomenin pánevního kruhu a acetabula. Acta Chir Orthop Traum Čech. 2011, 6, 568–577. ISSN 0001-5415
12. VAIDYA, R., COLEN, R., VIGDORCHIK, J. et al. Treatment of unstable pelvic ring injuries with an internal anterior fixator and posterior fixation: initial clinical series. J Orthop Trauma. 2012, 1, 1–8. ISSN 1531-2291.
Labels
Surgery Traumatology Trauma surgeryArticle was published in
Trauma Surgery
2014 Issue 4
Most read in this issue
- Compressive fractures of thoracic spine vertebras in children: diagnosis and treatment algorithm
- External fixation of distal radius fractures
- SUPPLEMENTATION OF OSTEOSYNTHESIS OF FEMUR BY AN INTERMEDULLARY NAIL – EXPERIMENTAL STUDY
- Stabilisation of the anterior pelvic ring segment by ©MATRIX Spine System