Swan-Ganz Catheter-induced Pulmonary Artery Rupture during Cardiac Surgery
Authors:
M. Šimek 1; Y. Plesníková; P. Němec; Lukáš Hruban; J. Klein
Authors‘ workplace:
Kardiochirurgická klinika FN Olomouc, přednosta doc. MUDr. P. Němec, CSc. 2I. chirurgická klinika FN Olomouc, přednosta prof. MUDr. V. Král, CSc.
1
Published in:
Anest. intenziv. Med., , 2004, č. 1, s. 32-35
Category:
Overview
The authors present the case report of Swan-Ganz catheter-induced pulmonary artery perforation during cardiac surgery,which wassuccessfully treated by pulmonary resection.Theyanalyzemechanismof catheter-induced injury and therapeuticoptions of this rare but often fatal complication with regard to patients undergoing cardiac surgery.
Key words:
hemoptysis – Swan-Ganz catheter – cardiac surgery – pulmonary hypertension – pulmonary resection
Labels
Anaesthesiology, Resuscitation and Inten Intensive Care MedicineArticle was published in
Anaesthesiology and Intensive Care Medicine
2004 Issue 1
Most read in this issue
- Importance of Diuresis for Diagnosis of Acute Renal Failure in Patients in Long-term IntensiveCare
- Anaesthesiological Technique with Endovascular Stentgraft Implantation for Aortic Aneurysms
- Postoperative Sedation with Dexmedetomidine in Patients after Off Pump Coronary ArteryBypass
- Prospective follow-up of the Patients with Hyperamylasemia after Cardiac Surgery