Automated preparation of radiopharmaceuticals as a tool of radiation protection optimisation of staff


Authors: Michal Budinský 1;  Petr Vyšinský 1;  Stanislav Synek 1;  Kateřina Žilková 2
Authors place of work: Masarykův onkologický ústav, Ústavní lékárna, Žlutý kopec 7, 656 53 Brno 1;  Oddělení nukleární medicíny, Fakultní nemocnice Hradec Králové 2
Published in the journal: Čes. slov. Farm., 2020; 69, 218-221
Category: Původní práce

Summary

Preparation of radiopharmaceuticals means everyday exposure to ionizing radiation for pharmaceutical workers. Manual preparation of positron radio-pharmaceuticals may be a risk in exceeding the legisla-tive limits for radiation workers, in particular in finger dosimetry. Instrumental methods of preparation of radiopharmaceuticals can serve as an effective tool of radiation protection. The present study deals with the evaluation of the results of personal dosimetry in workers preparing the radiopharmaceutical 18F-FDG with the use of instrumental methods of preparation of this radiopharmaceutical. The results of the paper show a clear decrease in the values of finger dosimetry and a minute increase in the values of whole-body dosimetry in the cohort of pharmaceutical personnel. The evaluation thus shows a clear contribution of instrumental methods of preparation of the radiopharmaceutical 18F-FDG to the results of finger dosimetry of pharmaceutical personnel.

Keywords:

automated preparation of radiopharma-ceuticals – radiation protection of staff – radiopharmacy


Zdroje

   1.  Demir M., Demir B., Yasar D., Sayman H. B., Halac M., Ahmed A. S., Ozcan K., Uslu I. Radiation doses to technologists working with 18F-FDG in PET center with high patient capacity. Nukleonika 2010; 55(1), 107–112.

   2.  Roberts F. O., Gunawardana D. H., Pathmaraj K., Wallance A., U P. L., Berlangieri S. U., Graeme J. O’Keefe, Rowe C. C., Scott A. M. J. Radiation dose to PET technologists and strategies to lower occupational exposure. J. Nucl. Med. Technol. 2005; 33, 44–47.

   3.  Guillet B., Quentin P., Waultier S., Bourrelly M., Pisano P., Mundler O. Technologist Radiation Exposure in Routine Clinical Practice with 18F-FDG PET. J. Nucl. Med. Technol. 2005; 33(3), 175–179.

   4.  Rohren E. M., Turkington T. G., Coleman E. Clinical applications of PET in oncology. Radiology 2004; 231, 305–332.

   5.  Bixler A., Springer G., Lovas R. Practical aspects of radiation safety for using fluorine-18. J. Nucl. Med. Technol. 1999; 27(1), 14–16.

   6.  Antic V., Ciraj-Bjelac O., Stankovic J., Arandjic D., Todorovic N., Lucic S. Radiation exposure to nuclear medicine staff involved in PET/CT practice in Serbia. Radiat. Prot. Dosim. 2014; 162(4), 577–585.

   7.  Schleipman A. R., Gerbaudo V. H. Occupational Radiation Dosimetry Assessment Using an Automated Infusion Device for Positron-Emitting Radiotracers. J. Nucl. Med. Technol. 2012; 40(4), 244–248.

   8.  Vanhavere F., Carinou E., Donadill L., Ginjaume M., Jankowski J., Rimpler A., Merce M. S. An overview of extremity dosimetry in medical applications. Radiat. Prot. Dosim. 2008; 123(1–3), 350–355.

   9.  Lecchi M., Lucignani G., Maioli C., Ignelzi G., del Sole A. Validation of a new protocol for 18F-FDG infusion using an automatic combined dispenser and injector system. Eur. J. Nucl. Med. Mol. Imag. 2012; 39, 1720–1729.

10.  Budinsky M., Kozakova S. Experience with instrumental methods in radiopharmacy as a tool of radiation protection optimization Eur. J. Oncol. Pharm. 2018; 1, 0002.

11.  Covens P., Berus D., Vanhavere F., Caveliers V. The introduction automated dispensing and injection during PET procedures a step in the optimisation of extremity doses and whole body doses of nuclear medicine staff. Radiat. Prot. Dosim. 2010; 140(3), 250–258.

12.  Nazififard M., Mahdizadeh S., Meigooni A. S., Alavi M., Suh K. Y. A novel device for automatic withdrawal and accurate calibration of 99mtechnetium radiopharmaceuticals to minimise radiation exposure to nuclear medicine staff and patient. Rad. Prot. Dosim. 2012; 151, 469–477.

13.  Lindner O., Busch F., Burchert W. Performance of a device to minimise radiation dose to the hands during radioactive syringe calibration. Eur. J. Nucl. Med. Mol. Imag. 2003; 30, 819–825.

14.  Nazififard M., Mahdizadeh S., Suh K. Y. Automated dispensing and calibrating of diagnostic radiopharmaceuticals. Radiat. Prot. Dosim. 2013; 154, 510–516.

Štítky
Farmacie Farmakologie

Článek vyšel v časopise

Česká a slovenská farmacie

Číslo 5-6

2020 Číslo 5-6
Nejčtenější tento týden
Nejčtenější v tomto čísle
Kurzy

Zvyšte si kvalifikaci online z pohodlí domova

plice
INSIGHTS from European Respiratory Congress
nový kurz

Současné pohledy na riziko v parodontologii
Autoři: MUDr. Ladislav Korábek, CSc., MBA

Svět praktické medicíny 3/2024 (znalostní test z časopisu)

Kardiologické projevy hypereozinofilií
Autoři: prof. MUDr. Petr Němec, Ph.D.

Střevní příprava před kolonoskopií
Autoři: MUDr. Klára Kmochová, Ph.D.

Všechny kurzy
Kurzy Podcasty Doporučená témata Časopisy
Přihlášení
Zapomenuté heslo

Zadejte e-mailovou adresu, se kterou jste vytvářel(a) účet, budou Vám na ni zaslány informace k nastavení nového hesla.

Přihlášení

Nemáte účet?  Registrujte se

#ADS_BOTTOM_SCRIPTS#