#PAGE_PARAMS# #ADS_HEAD_SCRIPTS# #MICRODATA#

Monitoring of indoor air of operating rooms in practice in a tertiary-type medical facility


Authors: L. Fedor 1,3,4;  O. Holý 2;  M. Nakládalová 3;  I. Matoušková 4;  L. Štěpánek 3
Authors‘ workplace: Oddělení nemocniční hygieny FN Olomouc a LF Univerzity Palackého v Olomouci, vedoucí MUDr. Jarmila Kohoutová 1;  Centrum vědy a výzkumu FZV Univerzity Palackého v Olomouci, ředitel doc. MUDr. Ondřej Holý, Ph. D. 2;  Klinika pracovního lékařství FN Olomouc a LF Univerzity Palackého v Olomouci, přednostka doc. MUDr. Marie Nakládalová, Ph. D. 3;  Ústav veřejného zdravotnictví LF Univerzity Palackého v Olomouci, přednostka prof. MUDr. Dagmar Horáková, Ph. D. 4
Published in: Pracov. Lék., 73, 2021, No. 3-4, s. 61-65.
Category: Original Papers

Overview

Adherence to aseptic conditions in the operating room is a key component in the prevention of healthcare associated infections. The aim of the work was to point out the effect of monitoring and evaluation of established anti-epidemic measures in operating rooms serving as tissue facilities in tertiary-type medical facilities in the order to ensure indoor air quality in preventing serious postoperative complications in patients. The work methodically describes the set monitoring of the indoor air of operating rooms in the periodicity once every six months by measuring the number of particles in the air and microbiological control of indoor air quality by an active method using an aeroscope. The limits applicable to clean rooms in pharmacy and tissue establishments based on good manufacturing practice and the technical standard EN ISO 14644-1: Clean rooms and relevant environmental management are used for evaluation. In the results, the authors present two case reports, which emphasize the importance of monitoring and especially its contribution to the setting of anti-epidemic conditions in operating rooms in the prevention of the spread of healthcare-associated infections, with regards to the presence of staff.

Keywords:

healthcare associated infections – operating rooms – clean rooms – indoor air monitoring – suspended dust particles – microbial flora


Sources

1. Andersen, B. M., Solheim, N. Occlusive scrub suits in operating theaters during cataract surgery: Effect on airborne contamination. Infect. Control Hosp. Epidemiol, 2002, 23, 4, s. 218–220.

2. Beldi, G., Bisch-Knaden, S., Banz, V., Mühlemann, K., Candinas, D. Impact of intraoperative behavior on surgical site infections. Am J Surg, 2009, 198, 2, s. 157–162.

3. Bhattacharya, A., Ghahramani, A., Mousavi, E. The effect of door opening on air-mixing in a positively pressurized room: Implications for operating room air management during the COVID outbreak. J. Build. Eng, 2021, 44, 102900, s. 1–9.

4. Cristina, M. L., Sartini, M., Schinca, E., Ottria, G., Spagnolo, A. M. Operating room environment and surgical site infections in arthroplasty procedures. J. Prev. Med. Hyg, 2016, 57, 3, s. 142– 148.

5. Dehghani, M., Sorooshian, A., Nazmara, S., Baghani, A. N., Delikhoon, M. Concentration and type of bioaerosols before and after conventional disinfection and sterilization procedures inside hospital operating rooms. Ecotoxicol Environ Saf, 2018, 164, s. 277–282.

6. EN ISO 14644-1:1999. Cleanrooms and associated controlled environments – Part 1: Classification of air cleanliness by particle concentration.

7. EN ISO/IEC 17025:2005. General requirements for the competence of testing and calibration laboratories.

8. Knobben, B. A. S., Horn, J. R., Mei, H. C., Busscher, H. J. Evaluation of measures to decrease intra-operative bacterial contamination in orthopaedic implant surgery. J Hosp Infect, 2006, 62, 2, s. 174–180.

9. Lee, S., Park, B., Kurabuchi, T. Numerical evaluation of influence of door opening on interzonal air exchange. Build. Environ, 2016, 102, s. 230–242.

10. Louart, B., Charles, C., Nguyen, T. L., Builles, N., Roger, C., Lefrant, J. Y., Vachiery-Lahaye, F., De Vos, J., Couderc, G., Muller, L. Microbial contamination and tissue procurement location: A conventional operating room is not mandatory. An observational study. PloS One, 2019, 14, s. 2–4.

11. Lynch, R. J., Englesbe, M. J., Sturm, L., Bitar, A., Budhiraj, K., Kolla, S., Polyachenko, Y., Duck, M. G., Campbell, D. A. Jr. Measurement of foot traffic in the operating room: implications for infection control. Am. J. Med. Qual, 2009, 24, 1, s. 45–52.

12. Macedo, J. I., Kubota, T. H., Matsumoto, L. S., Giordani, A. T., Takayanagui, A. M. M., Mendes, A. A., et al. Air quality in a hospital environment. Safety and Security Engineering, 2013, 134, s. 737–747.

13. Montagna, M. T., Rutigliano, S., Trerotoli, P., Napoli, C., Apollonio, F., D’Amico, A., De Giglio, O., Diella, G., Lopuzzo, M., Marzella, A., Mascipinto, S., Pousis, C., Albertini, R., Pasquarella, C., D’Alessandro, D., Serio, G., Caggiano G. Evaluation of Air Contamination in Orthopaedic Operating Theatres in Hospitals in Southern Italy: The IMPACT Project. Int J Environ Res Public Health, 2019, 16, 19, s. 1–2.

14. Mora, M., Mahnert, A., Koskinen, K., Pausan, M. R., Oberauner- Wappis, L., Krause, R., Perras, A. K., Gorkiewicz, G., Berg, G., Moissl-Eichinger, Ch. Microorganisms in Confined Habitats: Microbial Monitoring and Control of Intensive Care Units, Operating Rooms, Cleanrooms and the International Space Station. Front. Microbiol, 2016, 7,1573, s. 2–7.

15. Mousavi, E. S., Grosskopf, K. R. Airflow patterns due to door motion and pressurization in hospital isolation rooms. Sci. Technol. Built Environ, 2016, 22, 4, s. 379–384. 16. Mousavi, E. S., Jafarifiroozabadi, R., Bayramzadeh, S., Joseph, A., San, D. An observational study of door motion in operating rooms. Build. Environ, 2018, 144, s. 502–507.

16. Parikh, S. N., Grice, S. S., Schnell, B. M., Salisbury, S. R. Operating room traffic: is there any role of monitoring it? J. Pediatr. Orthoped, 2010, 30, 6, s. 617–623.

17. Rubina, A. Aerosolové a mikrobiální mikroklima čistého prostoru. In Sborník přednášek z konference SNEH, Brno: 2019 [23.10.2021]. Dostupné na www:

18. Rubina, A. Metodika postupu realizace VZT v čistých prostorách [online]. Brno: Ústav TZB, 2019 [2021-08-09]. Dostupné na www: . ISSN 1801-4399.

19. Sartini, M., Spagnolo, A. M., Panatto, D., Perdelli, F., Cristina, M. L. Improving environmental quality in an operating room: clinical outcomes and economic implications. J. Prev. Med. Hyg, 2013, 54, 2, s. 75–79.

20. Spagnolo, A. M., Ottria, G., Amicizia, D., Perdelli, F., Cristina, M. L. Operating theatre quality and prevention of surgical site infections. J. Prev. Med. Hyg, 2013, 54, 3, s. 131–137.

21. Standardní operační postupy pro vyšetřování mikroorganismů v ovzduší a pro hodnocení mikrobiologického znečištění ovzduší ve vnitřním ovzduší. J. SZU, 2002, 1. ISSN 0862-5956.

22. Státní ústav pro kontrolu léčiv. Čisté prostory, VYR-36. J. SUKL, [online] 2008 [2021-08-09]. Dostupné na www: . ISSN 1210-9460.

23. Vonci, N., De Marco, M. F., Grasso, A., Spataro, G., Cevenini, G., Messina, G. Association between air changes and airborne microbialcontamination in operating rooms. J. Infect. Public Health, 2019, 12, 6, s. 827–830.

24. Vyhláška č. 422/2008 Sb., o stanovení bližších požadavků pro zajištění jakosti a bezpečnosti lidských tkání a buněk určených k použití u člověka. Sbírka zákonu České republiky, částka 138.

25. Vyhláška č. 553/2007 Z. z., ktorou sa ustanovujú podrobnosti o požiadavkách na prevádzku zdravotníckych zariadení z hľadiska ochrany zdravia. Zbierka zákonov Slovenskej republiky č. 553/2007, čiastka 231.