The first employment of a single-use duodenoscope in the Czech Republic
Authors:
Urban O.; Falt P.
Authors‘ workplace:
II. interní klinika – gastroenterologická a geriatrická LF UP a FN Olomouc
Published in:
Gastroent Hepatol 2020; 74(5): 428-430
Category:
Digestive Endoscopy: Video-Case Report
Overview
Duodenoscopy-associated infections have been reported in several studies. A single-use duodenoscope enables examination of each patient with a sterile instrument. The first experience with single-use duodenoscope EXALTTM Model D in the Czech Republic is presented here as a video case report.
Keywords:
duodenoscope – disinfection – infection
Sources
1. Tachecí I, Urban O, Lukáš M et al. Vliv pandemie COVID-19 na endoskopickou praxi v České replublice-dotazníková studie. Gastroent Hepatol 2020; 74 (3): 195–203. doi: 10.14735/amgh2020195.
2. Ofstead CL, Wetzler HP, Snyder AK et al. Endoscope reprocessing methods: a prospective study on the impact of human factors and automation. Gastroenterol Nurs 2010; 33 (4): 304–311. doi: 10.1097/SGA.0b013e3181e9431a.
3. Bang JY, Sutton B, Hawes R et al. Concept of disposable duodenoscope: at what cost? Gut 2019; 68 (11): 1915–1917. doi: 10.1136/ gutjnl-2019-318227.
4. Rauwers AW, Troelstra A, Fluit AC et al. Independent root-cause analysis of contributing factors, including dismantling of 2 duodenoscopes, to investigate an outbreak of multidrug-resistant Klebsiella pneumoniae. Gastrointest Endosc 2019; 90 (5): 793–804. doi: 10.1016/j.gie.2019.05.016.
5. Rauwers AW, Voor In ‚t Holt AF, Buijs JG et al. High prevalence rate of digestive tract bacteria in duodenoscopes: a nationwide study. Gut 2018; 67 (9): 1637–1645. doi: 10.1136/gutjnl-2017-315082.
6. The FDA Continues to Remind Facilities of the Importance of Following Duodenoscope Reprocessing Instructions: FDA Safety Communication. 2019 [online]. Available from: https: //www.fda.gov/medical-devices/safety-communications/fda-continues-remind-facilities-importance-following-duodenoscope-reprocessing-instructions-fda.
7. Ross AS, Bruno MJ, Kozarek RA et al. Novel single-use duodenoscope compared with 3 models of reusable duodenoscopes for ERCP: a randomized bench-model comparison. Gastrointest Endosc 2020; 91 (2): 396–403. doi: 10.1016/j.gie.2019.08.032.
8. Muthusamy VR, Bruno MJ, Kozarek RA et al. Clinical Evaluation of a Single-Use Duodenoscope for Endoscopic Retrograde Cholangiopancreatography. Clin Gastroenterol Hepatol 2020; 18 (9): 2108–2117. doi: 10.1016/j.cgh.2019.10.052.
Labels
Paediatric gastroenterology Gastroenterology and hepatology SurgeryArticle was published in
Gastroenterology and Hepatology
Most read in this issue
- Proton pump inhibitors – do we know them well and are they really that safe? – part 1
- Budesonide in the treatment of idiopathic intestinal infl ammation
- New member of the editorial board MUDr. Kristýna Zárubová
- Predictors of advanced colorectal neoplasia in colorectal cancer screening – interim results of multicentric prospective study